Vegetation must not be allowed to grow within 3 feet of an exhaust vent.
Venting generator exhaust sbove roof line.
Perfect for those close together campsites.
This is an 18 extension pipe for the gen turi generator exhaust system.
It weighs only 9 lb.
4 wing bolts 1 4 20 thread size.
Exhaust vents must be protected against rain and equipped with back flow prevention features e g flap dampers.
This system is easy to install and disconnects quickly.
1 each large bungee cord.
It directs generator exhaust above the roof line while reducing noise.
It features powder coated pipes for rust heat resistance stainless steel heat shield quick easy disconnect and compact storage.
For normal or average sized generators there are several ways to go about this.
Instead both systems typically expel exhaust through a pipe that runs.
In all areas exhaust vents should be at least 1 foot above roof surface.
Where vents extend outdoors above the roof more than 5 feet 1524 mm higher than required by table 802 6 2 and where vents terminate in accordance with section 802 6 2 1 the outdoor portion of the vent shall be enclosed as required by this section for vents not considered to be exposed to the outdoors or such venting system shall be engineered.
Exhaust vents must not be allowed to be obscured or hidden by vegetation.
An added benefit is quieter generator operation.
The venting system is designed specifically for rv generators to help provide fresher air around rvs plus minimize generator noise.
While the gen turi system comes complete with 10 of pipe you may need a little extra if you have a taller rv and this extension will allow you to reach the recommended height.
1 each 3 inch hose clamp.
Venting your generators exhaust therefore becomes a task you want to embark upon.
1 each 3 inch drain pipe 1 foot length with cutout.
2 each 3 inch drain pipe 4 foot length longer if your motorhome is tall.
Direct venting and power venting systems offer greater flexibility because neither requires a direct line to the roof.
And has an overall length of 120.
The vent shall terminate at least 4 feet 1219 mm below 4 feet 1219 mm horizontally from or 1 foot 305 mm above any door window or gravity air inlet for the building.
It is recommended that the exhaust pipe extend a minimum of 6 above the roof line.
2 each 3 inch drain pipe couplers.
However the odds that the same is the case with your portable generator are pretty low.
2 each large suction cups with built in hooks.
18 extensions are available camco 44872 for taller rvs.
Divert those nasty fumes from your rv generator with the help of the camco gen turi generator exhaust venting system.